The least count for a weighing balance is the smallest value that the balance can display or measure. In a research laboratory, choosing the appropriate least count for a weighing balance is crucial for obtaining accurate and precise measurements. Here are some factors to consider when deciding the least count for a weighing balance:

Required precision: Consider the level of precision required for the research study. If the study requires high-precision measurements, a balance with a smaller least count should be used.

Size of sample: Consider the size of the sample being weighed. If the sample is small, a balance with a smaller least count may be necessary to obtain accurate measurements.


Accuracy of balance: The accuracy of the balance is also an important factor to consider. If the balance is not accurate, then even with a small least count, the measurements may not be reliable.

Available budget: The cost of the balance with a smaller least count will be higher than the balance with a larger least count. The available budget should be taken into consideration when deciding on the least count of the weighing balance.

Regulatory requirements: If the research study is subject to regulatory requirements, such as Good Laboratory Practice (GLP) or Good Manufacturing Practice (GMP), the least count of the balance should meet the regulatory requirements.

Once these factors have been considered, it is important to choose a balance with an appropriate least count that meets the requirements of the research study. It is recommended to consult with the manufacturer or supplier of the balance to ensure that the balance meets the required specifications.

What does 0.1 mg readability (d) mean?

Readability means, If you have a readability interval of d=0.0001g, it means that the smallest step you can read on it is 0.0001g (or 0.1mg), and increasing or decreasing the weight applied will change.

d= Readability (smallest increment of measurement displayed)

“d” for digit; digitus – lat. for finger (counting and calculating with the fingers is therefore a digital process)

If you have a readability interval of d=0.0001g, it means that the smallest step you can read on it is 0.0001g (or 0.1mg), and increasing or decreasing the weight applied will change.

What is the readability of 4 digit balance?

4 Digit Analytical Balance - 4 Digit Analytical Balance, Capacity: 220 G, Readability: 0.1mg, Minimum count weighing limit 100 mg.



What is (e) in analytical weighing balance?

e= Verification Scale Interval (Readability – Legal for Trade)

“e” is the verification scale interval (e is French for étalonné – verified; scala – Latin for the step of a stair) and represents the “readability of an approved balance”.

If a balance is approved, its last digit will appear in brackets. This means that for legal metrology the digits in brackets are visible but not valid, you must consider them.

In that case, the smallest step you are allowed to read is 1mg, the verification scale interval, therefore, is equal to ten digits, e=10d. This would be displayed on the inscription plate “e=1mg / d=0.1mg”.